63 research outputs found
The Medicina Station Status Report
General information about the Medicina Radio Astronomy Station, the 32-m antenna status, and the staff in charge of the VLBI observations is provided. In 2012, the data from geodetic VLBI observations were acquired using the Mark 5A recording system with good results. Updates of the hardware were performed and are briefly described
Software per acquisizione segnali Total Power polarimetrici a larga banda
Il presente documento ha l’obiettivo di descrivere la struttura e le funzionalità del sistema realizzato al fine di eseguire l’acquisizione dei segnali Total Power all’interno del progetto di Distribuzione IF presso il ricevitore di SRT. Sono presentati dapprima i componenti hardware del sistema, basato sull’utilizzo del controller CRIO-9056 insieme ai moduli di acquisizione NI 9205 commercializzati dalla National Instruments. Successivamente viene illustrato il software che rende possibile l’acquisizione, progettato in ambiente LabVIEW
Software per acquisizione segnali Total Power polarimetrici a larga banda - Manuale Utente
Il presente documento ha l’obiettivo di descrivere le funzionalità del software Data Client, realizzato per permettere il controllo da parte dell’Utente del sistema di acquisizione dei segnali Total Power all’interno del progetto di Distribuzione IF presso il ricevitore di SRT. Il sistema si basa sull’utilizzo del controller CRIO-9056 insieme ai moduli di acquisizione NI 9205, commercializzati dalla National Instruments, e su software progettato in ambiente LabVIEW.
Il software Data Client, eseguito sulla macchina server presente nel sistema, permette all’Utente di controllare l’esecuzione del software Real Time e quindi il processo di acquisizione svolto dalla scheda FPGA presente sui controller cRIO-9056. La programmazione del Data Client è avvenuta utilizzando il software LabVIEW Professional Development System for Windows
Software per la caratterizzazione e l’integrazione nel sistema di osservazione del SRT del ricevitore banda Q - Manuale Utente
Il presente documento ha l’obiettivo di descrivere le funzionalità del software denominato calibrate-multifeed-receiver, realizzato per agevolare la caratterizzazione e l’integrazione di un ricevitore. Il sistema si basa sull’utilizzo di un analizzatore di spettro, nello specifico i test sono stati effettuati con un Anritsu MS2830A visibile in Figura 1.1, di un software implementato in Python 3, e di un’interfaccia grafica scritta in Tk per facilitare l’operatore
Software per la caratterizzazione e l’integrazione nel sistema di osservazione del SRT del ricevitore banda Q - Relazione Tecnica
Il presente documento ha l’obiettivo di descrivere la struttura interna e le funzionalità del software denominato calibrate-multifeed-receiver, realizzato per agevolare la caratterizzazione e l’integrazione di un ricevitore. In particolare, questo software si focalizza sul ricevitore in banda Q che sarà posto nel sistema di osservazione del SRT Sardinia Radio Telescope. Si andrà dapprima a descrivere il setup hardware del sistema (Anritsu MS2830A), verranno poi introdotti e descritti (i) il package implementato in Python 3, (ii) l’interfaccia grafica scritta in Tk per facilitare l’operatore e (iii) la classe Python che si occupa di gestire l’hardware remoto
DBESM P1 (primo prototipo) Matrice di commutazione
Validazione del prototipo di scheda DBESM: na matrice di commutazione funzionale all'instradamento dei ricevitori ai back-end del sistema osservativo SR
Estimates of system noise temperature in W-band at SRT and effects of beam truncation due to the Gregorian radome
We report on system noise temperature estimates from the SRT site in W-band (70-116 GHz) based on recorded atmospheric data at four specific days, three-months apart, in the period 15 Oct. 2019-15 July 2020. The estimates are based on the atmospheric model described in [1] and on the feed-horn beams model and receiver noise specification of the W-band multibeam receiver being built for the Gregorian focus of the SRT.
We used different values for the antenna forward efficiency ηf to estimate the impact of such parameter on overall system noise Tsys. The beam truncation due to the 1 m diameter SRT Gregorian focus radome, which protects the receiver cabin from the atmospheric agents, is evaluated assuming that the cabin surrounding the radome contributes with a 293 K thermal noise (greater than the sky noise). The beams from the W-band receiver will be slightly truncated by the radome, especially at the lowest frequencies, where the beams are larger. We conclude that the effects of truncation on Tsys are negligible even in the scenario of lowest thermal emission from the sky, expected during winter season.
The estimated seasonal variations of the atmospheric conditions at the SRT show that, for the four specific days for which the system noise temperature was calculated, the Tsys have broad minima near the 3 mm band atmospheric window, around 85-105 GHz and achieves values of order 100 K or lower during winter. The system noise increases towards the W-band receiver band edges at 70 GHz and 116 GHz; the highest Tsys is obtained at the highest frequency of the band, 116 GHz, and reaches values beyond 200 K the 15th of October, 2019 and the 15th of July, 2020
Proposta di rinnovamento dell’antenna parabolica VLBI di Noto (SR)
Con questo rapporto tecnico si intendono spiegare alcuni interventi di ammodernamento che si intendono fare sull'antenna parabolica di Noto. Nello specifico si intendono rinnovare gli impianti tecnologici (elettrico, di raffreddamento acqua, dell'elio criogenico, della trasmissione dati) e aggiungere nuovi ripari per gli apparati anche in previsione dell'installazione del nuovo ricevitore tri-band previsto dal progetto PON "Ricerca e Innovazione"
Aggiornamento del sistema di controllo e di posizionamento del subriflettore e del ricevitore in fuoco primario Parabola VLBI di Noto (SR) 2021 Vol.3 – interventi a Noto (SR) – agosto e settembre 2021
Scopo del presente terzo volume (allegato ai volumi 1 e 2) è quello di dare una descrizione dei lavori di
rinnovamento della movimentazione del subriflettore svolti sulla antenna parabolica VLBI di Noto (SR) tra
agosto e settembre del 2021. Per tutti i dettagli tecnici specifici dell’apparato si rimanda ai volumi 1 e 2
Aggiornamento del sistema di controllo e di posizionamento del subriflettore e del ricevitore in fuoco primario Parabola VLBI di Noto (SR) 2021 Vol.2 – schemi elettrici e wire list
Questo volume è un completamento dei volumi 1 e 3 del rapporto tecnico “Aggiornamento del sistema di
controllo e di posizionamento del subriflettore e del ricevitore in fuoco primario”. In particolare questo
volume (2) è la raccolta degli schemi elettrici, di collegamento e wire list della nuova apparecchiatura
sviluppata. I file editabili e i singoli PDF, così come per i software applicativi del PLC e degli azionamenti
elettrici, sono reperibili presso gli autori del presente rapporto. In particolare, un primo schema era stato
sviluppato in OrCAD giĂ per la prima movimentazione gemella di Medicina e, in questo caso, oltre ad essere
stato aggiornato è stato rifatto anche in versione SPAC Automazione (dwg) per ulteriori possibilità di utilizzo
e compatibilità con il “mondo esterno” dell’automazione industriale
- …